Image 1 of 1
400K Indirect Fired LP/NG Heater
Manufacturer: Flagro USA
Model: HCI-400G (Dual Fuel – Propane / Natural Gas)
Overview
The Flagro HCI-400G 400K Indirect Fired Heater delivers clean, high-capacity heat using propane or natural gas, making it ideal for job sites where diesel isn't preferred or where clean-burning fuel options are required. With 400,000 BTU/hr of heat output, 4,000 CFM of airflow, and ducting capabilities up to 150 feet, this heater is built for large-scale temporary HVAC applications including construction, industrial facilities, events, and emergency response.
As an indirect-fired heater, the HCI-400G keeps all combustion byproducts outside the conditioned space, delivering safe, clean, fume-free heat through a stainless-steel heat exchanger. With a rugged frame and stackable design, it is optimized for jobsite mobility, storage, and reliability.
Key Features
400,000 BTU/hr heating capacity
Dual-fuel operation: Propane or Natural Gas
4,000 CFM high-volume airflow (ductable up to 150 ft)
Clean, safe heat — combustion stays outdoors
16 GA 304 stainless-steel heat exchanger
Stackable frame for efficient transport & storage
Backward-incline direct-drive blower for strong, consistent air output
Remote thermostat included (25' cord)
Multiple warm-air outlet sizes: (2) 12", (1) 16", (1) 20"
Return air inlet: 16"
115V / 15A electrical requirement
Technical Specifications
(From the specification table on page 1)
Performance
BTU/hr: 400,000
Airflow: 4,000 CFM
Ducting: Up to 150 ft
Fuel Type: Propane or Natural Gas
Fuel Supply: External
Air Connections
Supply Outlets:
(2) 12"
(1) 16"
(1) 20"
Return Air Inlet: 16"
Construction & Components
Heat Exchanger: 16 GA, 304 stainless steel
Burner Technology: Riello or Beckett burner
Blower: Backward-incline direct drive
Frame: Stackable on HCI-400G
Electrical
Power Requirement: 115V / 15A
Dimensions & Weight
Size (L × W × H): 74" × 29" × 60"
Weight: 380 lbs
Applications
Construction sites & cold-weather projects
Industrial and warehouse heating
Large event tents & temporary structures
Emergency response & disaster relief
HVAC support during shutdowns or retrofits
Oil & gas, mining, and remote operations
Why Choose the 400K Indirect Fired LP/NG Heater?
Clean-burning dual-fuel capability
Safe, fume-free heat for indoor spaces
Rugged, jobsite-ready stainless-steel heat exchanger
High-output heater suitable for large temporary HVAC needs
Flexible ducting for targeted heat distribution
Lower emissions compared to diesel alternatives
Request More Information
Download the Product Spec Sheet or contact our team for availability, fuel-type selection, and HVAC solutions tailored to your project needs.
Manufacturer: Flagro USA
Model: HCI-400G (Dual Fuel – Propane / Natural Gas)
Overview
The Flagro HCI-400G 400K Indirect Fired Heater delivers clean, high-capacity heat using propane or natural gas, making it ideal for job sites where diesel isn't preferred or where clean-burning fuel options are required. With 400,000 BTU/hr of heat output, 4,000 CFM of airflow, and ducting capabilities up to 150 feet, this heater is built for large-scale temporary HVAC applications including construction, industrial facilities, events, and emergency response.
As an indirect-fired heater, the HCI-400G keeps all combustion byproducts outside the conditioned space, delivering safe, clean, fume-free heat through a stainless-steel heat exchanger. With a rugged frame and stackable design, it is optimized for jobsite mobility, storage, and reliability.
Key Features
400,000 BTU/hr heating capacity
Dual-fuel operation: Propane or Natural Gas
4,000 CFM high-volume airflow (ductable up to 150 ft)
Clean, safe heat — combustion stays outdoors
16 GA 304 stainless-steel heat exchanger
Stackable frame for efficient transport & storage
Backward-incline direct-drive blower for strong, consistent air output
Remote thermostat included (25' cord)
Multiple warm-air outlet sizes: (2) 12", (1) 16", (1) 20"
Return air inlet: 16"
115V / 15A electrical requirement
Technical Specifications
(From the specification table on page 1)
Performance
BTU/hr: 400,000
Airflow: 4,000 CFM
Ducting: Up to 150 ft
Fuel Type: Propane or Natural Gas
Fuel Supply: External
Air Connections
Supply Outlets:
(2) 12"
(1) 16"
(1) 20"
Return Air Inlet: 16"
Construction & Components
Heat Exchanger: 16 GA, 304 stainless steel
Burner Technology: Riello or Beckett burner
Blower: Backward-incline direct drive
Frame: Stackable on HCI-400G
Electrical
Power Requirement: 115V / 15A
Dimensions & Weight
Size (L × W × H): 74" × 29" × 60"
Weight: 380 lbs
Applications
Construction sites & cold-weather projects
Industrial and warehouse heating
Large event tents & temporary structures
Emergency response & disaster relief
HVAC support during shutdowns or retrofits
Oil & gas, mining, and remote operations
Why Choose the 400K Indirect Fired LP/NG Heater?
Clean-burning dual-fuel capability
Safe, fume-free heat for indoor spaces
Rugged, jobsite-ready stainless-steel heat exchanger
High-output heater suitable for large temporary HVAC needs
Flexible ducting for targeted heat distribution
Lower emissions compared to diesel alternatives
Request More Information
Download the Product Spec Sheet or contact our team for availability, fuel-type selection, and HVAC solutions tailored to your project needs.